Meter Shunt Resistor FL2-F Shunt Resistor Current 200A For AMP Ampere Instrument Panel Black
1. Basic tolerance grade dimensions section
Tolerance grade | Basic dimension section | |||||
0.5-3 | >3-6 | >6-30 | >30-120 | >120-400 | >400-1000 | |
Roughness: C | 0.2 | ±0.3 | ±0.5 | ±0.8 | ±1.2 | ±2 |
2. Technology
Surface coating: nickel plating.
The surface of the resistor is coated: black amino baking enamel.
3. Technical data
Accuracy class | 0.5% |
Rated current in one time | 5A-1000A |
Rated voltage in 2 times | 75mV |
Environment temperature influence | Change 10℃ each, shunt output |
Overload capacity | 120% to rated current, continue 2h |
4. What's the electrical shunt resistor?
An ammeter shunt allows the measurement of current values too large to be directly measured by a particular ammeter. In this case the shunt, a manganin resistor of accurately known resistance, is placed in parallel with the moving coil galanometer, thus all of the current to be measured will flow through it. In order not to disrupt the circuit, the resistance of the shunt is normally very low. The voltage drop across the shunt is proportional to the current flowing through it and as its resistance is known, a voltmeter connected across the shunt can be scaled to directly display the current value.
5. Application Standards
Standards | Contents |
Environmental standards | Standards for the electronic industry of the People's Republic of China: SJ/T 11363-2006 quantity requirements. Eu: ROHS. |
Tolerance standard | The tolerance size is not specified in accordance with the national standard for Chinese migrant workers and the national standard: GB/ t1804-2000 rough C execution of general tolerances for linear and angular dimensions without tolerance. |
Product standard | National standard of the People's Republic of China: GB/ t766-1998 direct action simulation indicator electrical measuring instruments and their accessories professional standard of the People's Republic of China: JB/ t9288-1999 external attachment diverter. |
Safety standards | IEC61010-1:190 safety requirements for measuring, controlling and laboratory electrical equipment. Part 1: general requirements. |
6. Fixed setpoint shunt description
Application: The fixed setpoint shunt is a type of external shunt suitable for directly measuring the DC current below 10kA on the analog display instrument used to expand the DC current measurement range, or as a current in the sequential circuit. The standard resistor used for sampling can be regarded as the analog signal of the primary current for measurement.
7. Outside drawing
8. Electrical shunt usage